Appropriate training is essential for both Health & Safety reasons as well as to minimise potential damage to the machines and rotors. Machines must only be used by authorised users. All new members of staff and PhD students wanting to use the machines are required to attend a training session. They will then be added to the authorised users list. Training is provided by the Infrastructure Team biol-infrastructure-group@york.ac.uk. For new staff/PhD students, details are included in the Induction Pack. For existing users, training will be provided on request if you are not on the list of approved users.
An online booking system is in place; this is used along with Log Sheets for cross charging of the service
Location | Machine | Available Rotors | Notes |
A0 | High Speed Sorvall Evolution |
SLC-1500 |
Rotors are allocated to this specific machine and must not be moved. If the local machine does not have the required rotor, then book another machine that does. |
D0 | Floor standing Ultra Beckman 100XP | SW41Ti Type 45Ti Type 70Ti |
Remember to book both the machine and the relevant rotor. These are allocated to this specific machine but it is allowable to borrow rotors for use on different machines – providing they are returned to the allocated location after use |
D0 | High Speed Sorvall RC5B+ | SS34 | Rotors are allocated to this specific machine and must not be moved. If the local machine does not have the required rotor, then book another machine that does. |
D1 | High Speed Sorvall Evolution |
F21S (SS34) |
Rotors are allocated to this specific machine and must not be moved. If the local machine does not have the required rotor, then book another machine that does. |
H0 15 | Floor standing Ultra Beckman Optima XL-70 |
Type 70.1Ti |
View the full day page to see availability. Remember to book both the machine and the relevant rotor. These are allocated to a specific machine. |
H0 15 | High Speed Sorvall RC6 |
SS34 |
Rotors are specific to this machine and must not be moved. Rotors may be in the adjacent cold room. |
J0 03 | Benchtop Beckman Ultra Optima TL100 |
Vti 90 |
Rotors are specific to this machine, please discuss usage with Dr Paul Pryor |
K2 37 | Floor standing Ultra Beckman L60 | SW41Ti Type 45Ti Type 70.1Ti Type 70Ti |
Remember to book both the machine and the relevant rotor. These are allocated to this specific machine. The SW41Ti and the Ty45Ti belong to YSBL and must not be moved. If you use the Ty70.1Ti with a different machine please note this in your booking. |
K2 37 | High Speed Beckman Avanti J-26 |
JA-25.50 JLA-16.250 JLA-8.1000 |
Rotors are allocated to this specific machine and must not be moved. If the local machine does not have the required rotor, then book another machine that does. |
K2 37 | High Speed Beckman Avanti J-HC | JS-4.2A JLA 8.1000 |
Rotors are allocated to this specific machine and must not be moved. If the local machine does not have the required rotor, then book another machine that does. |
L0 28 | High Speed Sorvall Evolution | SS34 F10-S (6x500Y) F8S (6x1000) |
Rotors are allocated to this specific machine and must not be moved. If the local machine does not have the required rotor, then book another machine that does. |
L1 28 | Himac/Eppendorf CP80NX Ultra |
P80AT P40ST P45AT P32ST P50AT2 |
Remember to book both the machine and the relevant rotor. These rotors are specific to this machine. Rotors may be in the L1 cold room |
L1 28 | High Speed Sorvall Lynx (1) |
F9 (6x1000LEX) |
These rotors can only be used on the Sorvall Lynx. Do not attempt to use any other rotors on this machine. Do not use these rotors on any other centrifuges. |
L1 28 | High Speed Sorvall Lynx (2) |
F9 (6x1000LEX) |
These rotors can only be used on the Sorvall Lynx. Do not attempt to use any other rotors on this machine. Do not use these rotors on any other centrifuges. |
L1 31 | Table top Ultra Beckman TL100 | TLA-100 TLA-100.3 TLS-55 TLN 100 |
Remember to book both the machine and the relevant rotor. These are allocated to this machine only. |
M2 44 | High Speed Sorvall Lynx (3) |
F9-6x1000 |
These rotors can only be used on the Sorvall Lynx machines. Rotors from the Lynx 6000's in L128 may be used on this machine but on no others. These rotors can only be used on Lynx 6000 centrifuges. |
Instructions: Online booking via Infinity Idea Elan will guarantee your timeslot.
A decision on whether to retain individual machines is based on the actual level of use that is recorded in the booking system - low use machines may be re-located or not replaced. It is therefore vital that the booking system is used.